Volume 2, Issue 1 (Continuously Updated 2019)                   Func Disabil J 2019, 2(1): 37-45 | Back to browse issues page


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Didevara R, Aminian G, Daryabor A. The Effect of Ankle Angle and Foot-plate Length of Ankle-Foot Orthoses on Spatiotemporal Parameters and Knee Joint Angle in Post-Stroke Hemiplegic Gait. Func Disabil J 2019; 2 (1) :37-45
URL: http://fdj.iums.ac.ir/article-1-63-en.html
1- MSc. Of Prosthetics and Orthotics, Department of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
2- Associate Professor, Department of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran , gholamrezaaminia@yahoo.com
3- PhD Student Of Prosthetics and Orthotics, Department of Orthotics and Prosthetics University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
Abstract:   (2997 Views)
Background and Objectives:  Equinovarus deformity and knee hyperextension are the most common problems in stroke patients. Ankle foot orthosis (AFO) is commonly prescribed to improve these disorders in these patients, as well as gait parameters that are approved. The aim of this study is to investigate the effect of ankle alignment and rigid AFO footplate length on spatiotemporal parameters and knee joint angle in hemiplegic post-stroke patients.
Materials and Methods: This quasi-experimental study was performed on 6 hemiplegic post-stroke patients using three rigid AFO modes, including neutral ankle angle with full-length foot-plate -conventionally aligned AFO (CAFO), neutral ankle angle with ¾ length foot plate (¾AFO), and 50dorsi-flexion ankle angle with full-length foot-plate (50DF AFO) to investigate the effect of the alignment and foot plate length on spatiotemporal parameters and knee joint angle. The 3D motion analysis system with a Vicon Camera was used to collect the spatiotemporal parameters data.
Results: The mean walking speed of patients after using 50DF AFO was significantly higher compared to CAFO (P=0.036). The mean stride length, cadence and maximum knee extension angle in the stance phase during single limb support was not significantly different in the three different test modes of ¾AFO, CAFO, 50DF AFO (P > 0.05).
Conclusion: The DF AFO with 50ankle angle increases the walking speed and also controls knee hypertension in the terminal stance phase, which can be due to the progression of tibia in the mid to late stance phase and the alteration of ground reaction force vector.

 
Full-Text [PDF 436 kb]   (1079 Downloads) |   |   Full-Text (HTML)  (1785 Views)  
The DF AFO with 50ankle angle increases the walking speed and also controls knee hypertension in the terminal stance phase, which can be due to the progression of tibia in the mid to late stance phase and the alteration of ground reaction force vector.

Subject: Prosthetics and Orthotics
Received: 2019/01/9 | Accepted: 2019/03/13 | Published: 2019/05/8

References
1. Bovonsunthonchai, S., Hiengkaew, V., Vachalathiti, R., & Vongsirinavarat, M. (2011). Gait symmetrical indexes and their relationships to muscle tone, lower extremity function, and postural balance in mild to moderate stroke. Journal of the Medical Association of Thailand, 94(4), 476.
2. Chen, C., Yeung, K., Wu, S., & Chiang, P. (1998). Effects of an anterior ankle-foot orthosis on hemiplegic gait. J Rehabil Med Assoc ROC, 26, 119-127.
3. da Cunha Jr, I. T., Lim, P. A., Qureshy, H., Henson, H., Monga, T., & Protas, E. J. (2002). Gait outcomes after acute stroke rehabilitation with supported treadmill ambulation training: a randomized controlled pilot study. Archives of physical medicine and rehabilitation, 83(9), 1258-1265. [DOI:10.1053/apmr.2002.34267]
4. Danielsson, A., & Sunnerhagen, K. S. (2004). Energy expenditure in stroke subjects walking with a carbon composite ankle foot orthosis. Journal of rehabilitation medicine, 36(4), 165-168. [DOI:10.1080/16501970410025126] [PMID]
5. Easton, J. D., Saver, J. L., Albers, G. W., Alberts, M. J., Chaturvedi, S., Feldmann, E., Kidwell, C. S. (2009). Definition and evaluation of transient ischemic attack: a scientific statement for healthcare professionals from the American Heart Association/American Stroke Association Stroke Council; Council on Cardiovascular Surgery and Anesthesia; Council on Cardiovascular Radiology and Intervention; Council on Cardiovascular Nursing; and the Interdisciplinary Council on Peripheral Vascular Disease: the American Academy of Neurology affirms the value of this statement as an educational tool for neurologists. Stroke, 40(6), 2276-2293. [DOI:10.1161/STROKEAHA.108.192218] [PMID]
6. Eddison, N., Chockalingam, N., & Osborne, S. (2015). Ankle foot orthosis-footwear combination tuning: An investigation into common clinical practice in the United Kingdom. Prosthetics and orthotics international, 39(2), 126-133. [DOI:10.1177/0309364613516486] [PMID]
7. Fatone, S., Gard, S. A., & Malas, B. S. (2009). Effect of ankle-foot orthosis alignment and foot-plate length on the gait of adults with poststroke hemiplegia. Archives of physical medicine and rehabilitation, 90(5), 810-818. [DOI:10.1016/j.apmr.2008.11.012] [PMID]
8. Ferreira, L. A. B., Neto, H. P., Christovão, T. C. L., Duarte, N. A., Lazzari, R. D., Galli, M., & Oliveira, C. S. (2013). Effect of ankle-foot orthosis on gait velocity and cadence of stroke patients: a systematic review. Journal of physical therapy science, 25(11), 1503-1508. [DOI:10.1589/jpts.25.1503] [PMID] [PMCID]
9. Goldie, P. A., Matyas, T. A., & Evans, O. M. (1996). Deficit and change in gait velocity during rehabilitation after stroke. Archives of physical medicine and rehabilitation, 77(10), 1074-1082. [DOI:10.1016/S0003-9993(96)90072-6]
10. Hsu, J. D., Michael, J., & Fisk, J. (2008). AAOS Atlas of Orthoses and Assistive Devices E-Book: Elsevier Health Sciences.
11. Hung, J.-W., Chen, P.-C., Yu, M.-Y., & Hsieh, Y.-W. (2011). Long-term effect of an anterior ankle-foot orthosis on functional walking ability of chronic stroke patients. American journal of physical medicine & rehabilitation, 90(1), 8-16. [DOI:10.1097/PHM.0b013e3181fc7d27] [PMID]
12. Lamontagne, A., Malouin, F., & Richards, C. L. (2001). Locomotor-specific measure of spasticity of plantarflexor muscles after stroke. Archives of physical medicine and rehabilitation, 82(12), 1696-1704. [DOI:10.1053/apmr.2001.26810] [PMID]
13. Lee, H. Y., Lee, J. H., & Kim, K. (2015). Changes in angular kinematics of the paretic lower limb at different orthotic angles of plantar flexion limitation of an ankle-foot-orthosis for stroke patients. Journal of physical therapy science, 27(3), 825-828. [DOI:10.1589/jpts.27.825] [PMID] [PMCID]
14. Lehmann, J. F., Condon, S. M., & Price, R. (1987). Gait abnormalities in hemiplegia: their correction by ankle-foot orthoses. Archives of Physical Medicine and Rehabilitation, 68(11), 763-771.
15. Leung, J., & Moseley, A. (2003). Impact of ankle-foot orthoses on gait and leg muscle activity in adults with hemiplegia: systematic literature review. Physiotherapy, 89(1), 39-55. [DOI:10.1016/S0031-9406(05)60668-2]
16. Miyazaki, S., Yamamoto, S., & Kubota, T. (1997). Effect of ankle-foot orthosis on active ankle moment in patients with hemiparesis. Medical and Biological Engineering and Computing, 35(4), 381-385. [DOI:10.1007/BF02534094] [PMID]
17. Ohsawa, S., Ikeda, S., Tanaka, S., Takahashi, T., Takeuchi, T., Utsunomiya, M., . . . Katagi, Y. (1992). A new model of plastic ankle foot orthosis (FAFO (II)) against spastic foot and genu recurvatum. Prosthetics and orthotics international, 16(2), 104-108.
18. Silver-Thorn, B., Herrmann, A., Current, T., & McGuire, J. (2011). Effect of ankle orientation on heel loading and knee stability for post-stroke individuals wearing ankle-foot orthoses. Prosthetics and orthotics international, 35(2), 150-162. [DOI:10.1177/0309364611399146] [PMID]

Add your comments about this article : Your username or Email:
CAPTCHA

 

Designed & Developed by : Yektaweb